Quick engineering answer
When pneumatic conveying pressure drop rises, compare air supply, line-pressure profile, conveying-air flow and solids feed together. Separate insufficient air from excessive solids loading, buildup/partial plugging, leaking or mispositioned valves, and receiver/filter backpressure before changing blower pressure or feed rate.
Confirm pressure instruments, air flow and solids-rate signals are credible.
Distinguish high resistance from feed starvation or air leakage.
Check receiver/filter backpressure, feed device, valves, bends and buildup zones.
Repeat the same route test after correction and compare with the baseline.
Diagnostic starting point
Trend conveying pressure, solids rate, air flow, receiver pressure and filter differential pressure together. Compare the current profile with a stable operating baseline before changing blower or feeder settings.
High-pressure checks
- Line buildup or partial blockage.
- Restricted receiver or vent filter.
- Wet or cohesive material.
- Excessive feed rate.
- Incorrect route valve position.
Low-pressure checks
- Feed starvation.
- Air leakage.
- Worn feed-device seals.
- Reduced blower output.
- Instrument error.
Check the receiver and filter
The conveying line does not end at the pipe outlet. Rising pressure in the receiver, silo or vent filter adds backpressure to the entire system. Check filter differential pressure, cleaning performance, receiver level and discharge condition before opening the conveying line.
Check the feed device
Rotary valves and pressure-vessel discharge devices must introduce solids without losing excessive conveying air. Increased rotor-tip clearance, leaking seals or a valve that does not close correctly can reduce useful line pressure while increasing compressor demand.
Use pressure and throughput together
| Pressure | Throughput | Diagnostic direction |
|---|---|---|
| Rising | Falling | Restriction, buildup, receiver backpressure |
| Rising | Rising | Higher valid loading or approaching system limit |
| Falling | Falling | Feed starvation, leakage, blower/feed issue |
| Unstable | Unstable | Slugging, erratic feed, unstable air supply |
Practical troubleshooting sequence
- Verify pressure instruments.
- Record air flow and solids rate.
- Check receiver and vent-filter pressure drop.
- Inspect feed-device leakage.
- Confirm route valves and line configuration.
- Inspect bends and known buildup zones.
- Compare with a known-good pressure profile.
Dilute phase and dense phase are not judged the same way
Macawber defines dilute-phase conveying as operation at or above the material saltation velocity, while dense-phase conveying operates below saltation with higher solids loading. A pressure pattern that is normal for a pressure-vessel dense-phase system may be abnormal for a high-velocity dilute-phase line. Always compare with the design regime for that route.
When pressure rises slowly over days
A gradual rise at the same production rate is often more useful diagnostically than a single alarm. Check for developing line coating, filter loading, feed-device wear, moisture changes or a change in material fineness. Trending pressure per unit of solids throughput can help separate a process-rate increase from a real increase in resistance.
Pressure-profile field test
For a repeatable diagnostic test, hold the conveying route and material as constant as practical. Record blower discharge pressure, line or vessel pressure, air flow, solids throughput, receiver pressure and vent-filter differential pressure at fixed intervals from start-up through steady conveying and line clearing. Repeat the test at a comparable production rate after corrective work. This distinguishes a real reduction in system resistance from a temporary improvement caused by lower feed rate.
Decision matrix for common trends
| Trend | Priority checks | Interpretation |
|---|---|---|
| Pressure rises while air flow falls | Restriction, filter backpressure, blower operating point | System resistance is increasing |
| Pressure rises with stable air and falling solids | Line buildup, receiver restriction, route valve | More energy is being spent overcoming resistance |
| Pressure falls and air flow rises | Feed starvation, rotary-valve leakage, open bypass | Solids loading may have fallen |
| Sharp repeating pressure peaks | Slugging, vessel discharge sequence, unstable feed | Transient loading rather than uniform resistance |
Inspection sequence after a suspected restriction
Do not open the line until it has been safely isolated, depressurized and cleared according to the plant procedure. Start with non-invasive evidence: compare pressure taps, receiver/filter condition and known wear points. Then inspect the most probable restriction zones such as bends, diverter valves, low points and locations with a history of coating. Record the location and nature of deposits because recurring buildup often indicates a moisture, velocity or material-condition problem upstream.
Acceptance after corrective work
- Pressure instruments agree within their expected accuracy and respond normally.
- At comparable solids rate, the pressure profile returns toward the established baseline.
- Receiver/vent-filter differential pressure is stable.
- No abnormal air leakage is evident at the feed device or route valves.
- The system completes conveying and line clearing without repeated high-pressure trips or unstable slugging.
If the line repeatedly requires higher pressure to maintain the same throughput, investigate the developing resistance instead of simply increasing the pressure limit. The safe operating envelope remains governed by the equipment and piping design ratings.
Reference basis
See Macawber’s Pneumatic Conveying Terminology for definitions of conveying pressure, dilute phase, dense phase and solids loading. Coperion’s pneumatic-conveying technical work also uses full-scale test systems to evaluate conveying pressure and material behavior.