BRANDO CA25T 1-Inch Pulse Jet Valve | Request Quotation

Cement Plant Spare Parts / Baghouse Valves

Dust collector components · BRANDO

CA25T · 1-inch Integral Pilot Pulse Jet Valve

Right-angle diaphragm valve for compressed-air reverse-pulse cleaning in compatible industrial baghouses and dust-collection systems.

B2B COMMERCIAL ENQUIRY

Request a firm quotation

Final unit price, quantity breaks, availability, freight, duties and delivery terms are quoted after confirming your exact technical specification and destination.

Request price & availability
Check specifications

Product identification: INF-CA25T-G1-220AC-NBR · Supply against confirmed specification

Product & Application Gallery

Illustrative product rendering of a 1-inch integral-pilot diaphragm pulse jet valve with solenoid coil; not an official manufacturer photograph
Product appearance — illustrative rendering, not a manufacturer photograph. Exact supplied unit must match the written offer.
Illustrative example of pulse valves connected to a compressed-air header at an industrial baghouse installation
Typical baghouse application — conceptual installation view, not an installation or connection instruction.
Engineering fit review

Check port type, coil rating and existing-valve references before issuing a firm offer.

Documented quotation

Quantity, dispatch terms, shipping charges and payment conditions are stated in writing.

International enquiries

Provide delivery city and country for a destination-specific shipping quotation.

Technical Specifications

The following details describe the BRANDO CA25T product family and requested supply configuration. Exact coil frequency, G1 thread and diaphragm selection will be verified against the manufacturer’s offered model before confirmation.

Manufacturer / rangeBRANDO · CA25T / T-Series
Valve constructionRight-angle, integral-pilot diaphragm valve
Nominal port / orifice1 inch / approximately DN25
Connection requestedG1 (BSP) female threaded, confirmation required
Coil requested220VAC; frequency and connector to be confirmed
Diaphragm requestedNBR (nitrile); alternative FKM variants exist
Body materialDie-cast aluminum
Operating mediumClean compressed air
Manufacturer-listed working pressure0.35–0.85 MPa (3.5–8.5 bar); verify exact variant
Sales unitEach · one complete valve per unit

Technical verification: request the manufacturer datasheet, dimensional drawing and coil specification through Infinity’s procurement team. Final supplied configuration is confirmed against the customer’s RFQ.

How a Pulse-Jet Cleaning System Works

The controller energizes the solenoid pilot, releasing the pressure that holds the main diaphragm closed. The valve opens briefly, discharging compressed air into the cleaning tube to pulse the filter row.

Conceptual schematic of controller, solenoid coil, pilot valve, compressed-air header, diaphragm pulse valve, blow tube, filter bags and dust hopper
Conceptual system illustration. Not a manufacturer drawing, validated piping schematic, electrical diagram or installation specification.

Application & Selection

CA25T pulse valves are used to release timed bursts of compressed air into suitable dust-filter cleaning circuits. Applications may include baghouse dedusting at cement handling, conveying and silo processes. Valve choice must be based on installed equipment—not solely on nominal pipe size.

Before ordering, please verify

  • Installed valve manufacturer, model, connection arrangement and available clearance
  • G/BSP versus NPT or Rc pipe thread and actual connection size
  • Coil voltage, AC frequency and plug/terminal connection
  • Diaphragm material and operating pressure at the valve
  • Quantity, plant destination and requested delivery date

Interchangeability: This offer concerns a BRANDO-manufactured aftermarket valve. It is not a genuine Goyen/Pentair product, and no OEM-authorized interchangeability is claimed. Physical and functional compatibility must be approved for the installed system.

Technical Buying Questions

Does a high baghouse differential pressure mean the valve has failed?

Not necessarily. Dust loading, blinded media, wet compressed air, inadequate header pressure, control timing or malfunctioning diaphragm valves can all reduce cleaning performance. Fault-isolate the air supply and valve sequence before selecting a replacement.

Is this valve interchangeable with a Goyen CA25T?

The BRANDO valve is a Goyen-type aftermarket design, not genuine Goyen equipment. Match mechanical dimensions, threads, solenoid rating, diaphragm and installed arrangement; do not assume interchangeability from the series name.

How is the final unit price determined?

Our written commercial offer specifies the valve configuration, order quantity, applicable shipping charges, commercial terms and delivery location. Duties, taxes and installation are identified separately when applicable.

What information speeds up an accurate RFQ?

Send quantity, voltage/frequency, pipe-thread type, nameplate or drawing, delivery country and required date. We will confirm the available configuration before accepting an order.

Engineering Resources

For diagnosis before replacement, review the pulse-valve slow-response guide and diaphragm leakage and weak-pulse troubleshooting. These resources explain why a valve should be specified after identifying the actual failure mechanism.

Ordering & Delivery

Send an enquiry with your quantity, destination, existing valve reference and required specification. A formal quotation will confirm the supplied configuration, final unit price, shipping terms, expected lead time, warranty conditions and payment method. No online payment is collected on this page.

Request a Commercial Quotation

Send your technical requirement to Infinity’s procurement desk. Include the installed valve model or nameplate photograph where available.

Email purchase enquiry

Or email [email protected] with subject BRANDO CA25T RFQ.

Infinity for Cement Organization provides independent industrial sourcing and procurement support. Trademarks are used for identification; manufacturer authorization is not implied.

10 Essential Cement Plant Calculations

Free PDF — clinker chemistry, kiln sizing, ball mill power, and more. Enter your email and we'll send it immediately.

No spam. Unsubscribe anytime.

Check Your Inbox

Your PDF is on its way. Plus 6 more emails with cement plant tips and case studies.