Every kiln has a fuel bill and a limit on how much of that fuel turns into clinker. A heat balance shows the gap. It lists every kJ that goes into the kiln system and every kJ that comes out, per kg of clinker, so you can see which loss is worth chasing first. This guide walks through one on a dry-process preheater kiln, with a worked example you can follow with a calculator.
What a heat balance is
It is an energy accounting for a control volume. Draw a boundary around the kiln, preheater and cooler. Everything that crosses the boundary is counted. Inputs equal outputs, and whatever you cannot measure ends up in one balancing line (radiation, convection and unaccounted losses). Use a reference temperature (0 C is common, 20 or 25 C also works) and keep it the same for every line.
Step 1: Choose the basis and the boundary
- Basis: 1 kg of clinker. This lets you compare kilns and days.
- Boundary: from the raw meal feed to the preheater, to the clinker leaving the cooler. State clearly whether the raw mill, coal mill or calciner fuel is inside.
- Averaging period: use an operating period when kiln feed, fuel rate and temperatures were stable, typically a few hours to a day. A heat balance on a kiln that was upset is not representative.
Step 2: Collect the data
- Clinker production (t/h) from weigh feeder and loss on ignition, or from clinker weighing.
- Fuel rate (t/h) and its net calorific value (NCV) from the lab, kJ/kg.
- Raw meal feed and its moisture, temperature and specific heat.
- Preheater exit gas flow, temperature, and composition (O2, CO2, CO).
- Dust loss with the exit gas.
- Clinker and cooler vent air temperatures and flows.
- Shell temperatures for the radiation estimate, or take it as the balancing term.
Step 3: The heat inputs
The dominant input is fuel: fuel rate per kg clinker times NCV. Add the sensible heat of the raw meal, fuel and any air entering the system, each as mass x specific heat x (temperature – reference).
Step 4: The heat outputs
- Heat of clinker formation. About 1,750 kJ/kg clinker (roughly 420 kcal/kg) for a typical Portland clinker. This is the useful part, the heat the reactions need. It depends on the raw mix chemistry, so use the figure from your own composition when you have it.
- Moisture evaporation. Water in the raw meal and fuel times the latent heat (about 2,440 kJ/kg of water near ambient temperature).
- Exit gas. Mass of gas x specific heat x (exit temperature – reference). The gas includes combustion products, calcination CO2 and false air. This is usually the largest loss.
- Dust. Dust carried out with the gas, at gas temperature.
- Clinker. Clinker leaving the cooler, at its discharge temperature.
- Cooler vent air. Air leaving the cooler to the stack or to a waste heat system.
- Radiation and convection. From shell and surface temperatures, or the difference that closes the balance.
Worked example (illustrative numbers)
The numbers below are round figures chosen for the example. They are not measurements from a specific plant. Basis: 1 kg of clinker, reference temperature 0 C, dry-process preheater kiln.
Heat in
| Item | kJ/kg clinker | % of input |
|---|---|---|
| Fuel combustion (0.128 kg coal/kg clinker x 25,000 kJ/kg) | 3,200 | 97.4% |
| Sensible heat of raw meal (1.55 kg at 60 C, cp 0.84) | 78 | 2.4% |
| Sensible heat of fuel (0.128 kg at 40 C, cp 1.26) | 6 | 0.2% |
| Total | 3,285 | 100% |
Heat out
| Item | kJ/kg clinker | % of input |
|---|---|---|
| Heat of clinker formation (theoretical) | 1,750 | 53.3% |
| Evaporation of raw meal moisture (0.5%) | 19 | 0.6% |
| Preheater exit gas (2.0 kg at 330 C, cp 1.12) | 739 | 22.5% |
| Dust leaving with the gas (0.08 kg at 330 C) | 25 | 0.8% |
| Clinker leaving the cooler (1.0 kg at 110 C, cp 0.85) | 94 | 2.8% |
| Cooler vent air (1.2 kg at 250 C, cp 1.02) | 306 | 9.3% |
| Radiation, convection and unaccounted (by difference) | 352 | 10.7% |
| Total | 3,285 | 100% |
The specific heat consumption is the fuel line: 3,200 kJ/kg clinker, about 764 kcal/kg. Modern multi-stage preheater and precalciner kilns often operate roughly in the 3,000 to 3,500 kJ/kg range. Older or wet-process kilns need considerably more. Compare your own number with kilns of the same type, not with the best in the world.
How to read the result
- The formation heat is the floor. You cannot burn below it, so the gap between your fuel line and about 1,750 kJ/kg is what you can work on.
- Exit gas is the first place to look. Lower exit gas temperature or less false air reduces this line directly. Check air ingress at the kiln seals and the preheater, and the O2 at the kiln inlet.
- Cooler vent loss points at cooler performance: grate loading, air distribution, and how much heat goes back to the kiln as secondary and tertiary air.
- A large balancing line usually means a measurement problem or high shell losses. Re-check gas flow first, because it is the least certain number. Do not tune the kiln on a balance that does not close within a few percent of the input.
Common mistakes
- Mixing reference temperatures between lines.
- Using gross calorific value for fuel when the other lines are net, or the reverse. Pick one and say which.
- Taking gas flow from a single reading rather than an average.
- Forgetting the heat of the calcination CO2 and moisture in the gas mass.
- Balancing a kiln that was not in steady operation.
Try it
You can run the same arithmetic in the free Kiln Heat Balance Calculator on this site. It gives a quick screening of the main lines per kg of clinker. For a full set of kiln, mill, burner and cooler worksheets, see the Cement Engineering toolkits.
Related: Cement Kiln Heat Balance (background and equations).
This article is an educational overview. A real heat balance needs plant measurements, and the final figures should be checked against your plant data and applicable standards before decisions are made.