
Quick answer
When the air‑to‑solids ratio (ASR) drifts while blower speed remains constant, the most common cause is a change in system resistance – typically due to pipe fouling, valve position shift, or unexpected air leakage. Verify the blower’s operating point, inspect for pressure drop changes, and confirm that the air flow controller is functioning correctly before adjusting the blower speed.
Problem / Job
The pneumatic conveying line is delivering cement clinker or fine powder at a steady blower RPM, but the measured ASR is gradually increasing. The process is showing signs of reduced conveyance efficiency, higher power draw, and occasional material buildup in the pipeline.
Evidence
- Blower speed (RPM) unchanged for > 48 h.
- Air flow sensor indicates a higher volumetric flow at the same speed.
- Pressure differential across the main line has increased.
- Material accumulation observed at bends and bends‑to‑vertical transitions.
- Power consumption of the blower has risen by 5‑10 %.
Decision
Prioritize a systematic check of the conveying loop for added resistance, verify instrumentation accuracy, and confirm that the blower’s performance curve matches the current operating point. Only after ruling out mechanical and measurement issues should the control set‑point be adjusted.
7‑step diagnostic workflow
- Secure the line. Isolate the blower and downstream equipment using lock‑out/tag‑out (LOTO) procedures. Depressurize the conveying line, verify zero pressure with a calibrated gauge, and post a safety barrier before any physical inspection.
- Confirm instrumentation. Cross‑check the air flow meter, pressure transducers, and temperature sensors against calibrated reference devices. Record any deviation and recalibrate if the error exceeds the manufacturer’s tolerance.
- Review blower performance data. Retrieve the latest run‑chart for blower speed, power draw, and inlet/outlet pressures. Compare the current operating point with the OEM‑provided performance curve to ensure the blower is still operating within its design envelope.
- Measure pressure drop. Using a portable differential pressure gauge, measure the pressure loss across key sections: inlet filter, main line, bends, and the discharge valve. Document the values and compare them with baseline data from commissioning.
- Inspect for physical obstructions. With the line isolated, visually examine pipe interiors (using borescopes where possible) for fouling, material buildup, or damaged wear plates. Clean or replace components as required.
- Check for air leakage. Perform a leak‑down test by pressurizing a short segment of the line and monitoring pressure decay. Identify any seals, gaskets, or couplings that are losing air and repair them.
- Validate control logic. Review the PLC or DCS logic that translates blower speed to air flow set‑point. Ensure that the controller is not compensating for a sensor drift or a mis‑configured gain that would artificially raise the ASR.
After completing the steps, re‑establish normal operation, monitor the ASR for at least two full production cycles, and document any adjustments made.
Diagnostic matrix
| Evidence | Likely direction of root cause | Next check / action |
|---|---|---|
| Increasing pressure differential across the main line | Added hydraulic resistance (fouling, wear‑plate wear, valve partially closed) | Inspect pipe interior, clean fouling, verify valve position |
| Air flow sensor reads higher volume at constant RPM | Sensor drift or calibration error | Cross‑check with calibrated flow meter; recalibrate if needed |
| Blower power draw up 5‑10 % | Blower operating farther up its curve due to higher system back‑pressure | Plot current point on OEM performance curve; confirm within design limits |
| Visible material buildup at bends | Reduced conveyance velocity causing local stagnation | Clean affected sections; evaluate whether pipe geometry meets design |
| Pressure decay during leak‑down test | Air leakage in seals, couplings, or filter housing | Tighten or replace leaking components; retest for pressure hold |
| Control set‑point trending upward without operator input | Control algorithm compensating for perceived low flow | Review PID parameters; confirm sensor integrity; adjust logic if required |
| Temperature rise in the conveying line | Higher gas density increasing mass flow for same volumetric flow | Check temperature compensation in flow measurement; adjust calculations |
Acceptance / verification criteria
- Air‑to‑solids ratio returns to the baseline value recorded during commissioning and remains within ±5 % for three consecutive production runs.
- Pressure differential across the main line matches the design‑specified drop (verify against OEM or site‑specific data) and does not exceed the documented maximum.
- Blower power consumption stabilizes at the value indicated on the performance curve for the current operating point, with no unexplained increase.
- All flow, pressure, and temperature sensors pass a calibration check within the tolerance specified by the equipment manufacturer.
- No audible or visual signs of material accumulation after a minimum of 24 h of continuous operation.
- Leak‑down test shows pressure decay of less than the allowable percentage defined by the system design (typically < 0.5 % per hour).
Document each verification step with timestamps, instrument readings, and the responsible technician’s signature. Retain the records for the next scheduled maintenance audit.
Common mistakes and repeat‑failure traps
- Adjusting blower speed before confirming system resistance. Changing RPM can mask the underlying pressure‑drop issue and lead to over‑pressurization downstream.
- Relying on a single flow sensor. A faulty or drifted sensor will drive the control loop into an incorrect set‑point, perpetuating the ASR drift.
- Skipping LOTO during pipe inspection. Uncontrolled air release can cause sudden pressure spikes, endangering personnel and damaging equipment.
- Neglecting temperature compensation. Air density changes with temperature; failing to account for this can produce apparent ASR changes that are purely thermodynamic.
- Cleaning only visible fouling. Hidden buildup in vertical sections or behind wear plates can sustain elevated pressure drop even after a superficial clean.
- Over‑tightening valves or actuators. A valve that is marginally closed will increase system resistance while appearing “fully open” to the operator.
- Failing to update the control logic after hardware changes. Replacing a filter or adding a new bend without adjusting the controller’s gain can cause the system to chase an unattainable flow target.
Address each of these pitfalls during the diagnostic workflow to prevent recurrence and to maintain a stable ASR without unnecessary blower speed changes.
Related Infinity guides
Build a stronger cement maintenance library
The Infinity for Cement Organization technical package contains 900+ technical files. It is a one-time $249.99 purchase, with instant download immediately after payment and lifetime updates forever at no additional cost.
