Pilot Burner Capacity Calculator — Kiln & Burner Sizing — cementequipment.org

Pilot Burner Capacity Calculator

Size your rotary kiln burner, calciner burner, and pilot oil burner based on plant capacity, coal quality, and preheater configuration.

Kiln & Burner Parameters







The calciner split (auto-set from preheater stage) determines distribution between kiln and calciner burner.


Results

Enter kiln parameters and click Calculate.

Preheater Stage Reference

Preheater Stage Kiln Burner Split (%) Notes
IV Stages 50 Older plants / smaller kilns
V Stages 55 Common modernization target
VI Stages 60 Modern high-efficiency plants
Note: The kiln burner split increases with more preheater stages as more calcination shifts to the calciner. The pilot burner is sized at 30% of the kiln burner heat output (fuel oil assumed at 9,000 kcal/L).

How It Works

1. Heat Required
Heat = Capacity × Sp. Heat Consumption (kcal/hr)
2. Burner Split
% to Kiln vs Calciner based on preheater stages
3. Mass Flow
Burner (tph) = (Split% × Heat) / (CV × 24)
4. Pilot Sizing
Pilot = 30% of kiln burner heat output

10 Essential Cement Plant Calculations

Free PDF — clinker chemistry, kiln sizing, ball mill power, and more. Enter your email and we'll send it immediately.

No spam. Unsubscribe anytime.

Check Your Inbox

Your PDF is on its way. Plus 6 more emails with cement plant tips and case studies.

Ask a Cement Engineer ×
Hello! Ask me any cement plant technical question — kiln, grinding, quality, maintenance, preheater. I'll give you a practical answer.